Summary for Capturing
  • Create a new database (set the directory where the data will be stored)
  • Connect the cameras
  • click Camera Layout (Under Studio Activities tab) (circle fit)
    • set strobe to 1, threshold to .3, gain to 2, leave circular at .5
    • run autothreshold (start/stop)
    • wand wave (start, wave, stop)
    • set origin (wand in center, start, stop)
    • set floor (distributed markers, start, stop)
    • save calibration (just incase - you can re-load calibration - now settings and location saved) save to an xcp file.
  • click Capture Layout and then go ahead and capture ROM - creates x2d raw capture data
  • process ROM (click Actor Layout - Labeling and Solving steps) - creates the vsk skeleton, and save the vss